Description
On/Off Switch for Pro Shaker Machine All Versions
Instructions:
- Remove the two screws from the base of the shaker (0:04)
- Stand the unit upright and gently remove the cover from the back (0:17)
- If you hold the cover in one hand, you should be able to unplug the circuit board (PCB) from the cover.
(0:20) - There are two connectors coming out of the board: a long green one with the red switch on the end and a white connector with red and black wires coming from it. Carefully unplug the green connector from the board (0:23)
- Disconnect the white connector holding the red and black wires from the board and discard the old PCB (0:37)
- Connect the white connector from Step 5 to your new PCB (0:44)
- Pull the old switch out from the cover (0:50)
- Insert the green tail from the new switch into the cover until only the red tab is left sticking out (0:58)
- Remove the paper backing from behind the red tab and press the red tab into the designated circular area in the cover (1:06)
- Insert the green connector end of the switch into the slot on the PCB and secure it (1:30)
- Slide the black piece of the CB back into the cover (1:35)
- Place the cover back onto the ProShaker (1:38)
- Turn the ProShaker back onto its face and fasten the two screws into the base to secure the cover back to the unit (1:41)
Payment & Security